V4055A1007 Honeywell Actuator, On-Off Fluid Power Gas
Actuator, On-Off Fluid Power Gas Valve Actuator, 120Vac, 26 Second Opening Timing, 1 Second or Less Closing Timing, 5 Psi Maximum Operating Pressure, -40-150 Degree Temperature Range
Honeywell
V4055A1007
085267104180
Not in stock
V4055A1064 Honeywell Motorized Gas Valve Actuator. 120V.
Motorized Gas Valve Actuator. 120V. 26 Sec Timing. With Damper Shaft. Use With V5055A & B Low Pressure Valve Bodies.
Honeywell
V4055A1064
085267104203
20 In Stock
V4055A1098 Honeywell Thermal Motorized Gas Valve Actuator. 120V.
Motorized Gas Valve Actuator. 120V. 13 Sec Timing. With Damper Shaft. Use With V5055A & B Low Pressure Valve Bodies.
Honeywell
V4055A1098
085267104227
20 In Stock
V4055A1296 Honeywell Actuator, On-Off Fluid Power Gas
Actuator, On-Off Fluid Power Gas Valve Actuator, 120Vac, 13 Second Opening Timing, 1 Second or Less Closing Timing, 5 Psi Maximum Operating Pressure, -40-150 Degree Temperature Range, Internal Auxiliary Switch Adjusted to 90% Stroke, Used with V5055/V5097A,B Series Valve Bodies
Honeywell
V4055A1296
085267104333
Not in stock
V4055D1001 Honeywell Gas Valve Actuator With Proof Of
Gas Valve Actuator With Proof Of Closure switch. 120V. 26 Second Opening Time. 1 Second Spring Close. Includes Damper Shaft. Use With V5055 Valves.
Honeywell
V4055D1001
085267104456
5 In Stock
V4055D1019 Honeywell Motorized Gas Valve Actuator. 120V.
Motorized Gas Valve Actuator. 120V. 13 Sec. Timing. W/Damper Shaft. Use WithV5055C Valve Bodies. Incl. Proof Of Closure And Valve Seal Over travel Interlock Switches.
Honeywell
V4055D1019
085267104463
18 In Stock
V4062A1008 Honeywell Gas Valve Actuator 120V HI-LO-OFF
Gas Valve Actuator 120V HI-LO-OFF actuator. 26 second opening time. Add 133568 Aux Switch to replace obsolete V4062A1123. *
Honeywell
V4062A1008
085267104562
5 In Stock
V4062A1131 Honeywell Gas Valve Actuator
Gas Valve Actuator High-Low-Off Gas Valve Actuator For V5055B Valve Bodies 120V. 13 Second Opening Time. 1 Second Spring Closure. Includes Damper Shaft.
Honeywell
V4062A1131
085267104623
4 In Stock
V4062D1002 Honeywell Valve actuator H-L-O POC
Valve actuator H-L-O POC * Gas valve actuator. 120 volts. Hi Lo Off with proof of closure switch. 26 second opening. Maximum pressure 5 PSI. Must use V5055/V5097C,E valve bodies. Opening 59.5 watts, 129 VA. Holding 19 watts, 28VA. Damper shaft. Temp range -40 to 150F
Honeywell
V4062D1002
085267104647
1 In Stock
V4295A1015 Honeywell 1/2NPT Sol Gas Valve 2PSI NC
1/2NPT Sol Gas Valve 2PSI NC * Normally closed solenoid gas valve. 120 volts. 1/2 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 2 PSI. 250 CFH. .16 amps.
Honeywell
V4295A1015
4046911014091
16 In Stock
V4295A1023 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 3/4 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 2 PSI. 645 CFH. .16 amps.
Honeywell
V4295A1023
085267149969
4 In Stock
V4295A1031 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 1 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 2 PSI. 790 CFH. .16 amps.
Honeywell
V4295A1031
085267149976
7 In Stock
V4295A1049 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 1-1/4 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 2 PSI. 1450 CFH. .34 amps.
Honeywell
V4295A1049
085267149983
1 In Stock
V4295A1056 Honeywell Solenoid gas valve. 1-1/2 inch. 120
Solenoid gas valve. 1-1/2 inch. 120 volts. 2190 CFH. 2 PSI. .3amp draw.
Honeywell
V4295A1056
085267149990
3 In Stock
V4295A1064 Honeywell 2 Sol Gas Valve 2psi 120vac
2 Sol Gas Valve 2psi 120vac * Normally closed solenoid gas valve. 120 volts. 2 inch NPT. 3465 CFH. Max pressure 2 PSI. .525 amps current. Mounting vertical to 90 degrees. Temp range -40 to 140F. Pressure taps on both sides.
Honeywell
V4295A1064
085267150002
Not in stock
V4295A1072 Honeywell Solenoid gas valve 2-1/2 NPT. 120
Solenoid gas valve 2-1/2 NPT. 120 volts. Normally Closed. 2 PSI. 5070 CFH. -40 to 145F operating temp.
Honeywell
V4295A1072
085267150019
Not in stock
V4295A1098 Honeywell Solenoid gas valve. 3/8 NPT. 120
Solenoid gas valve. 3/8 NPT. 120 volts. Normally closed. Max pressure 5 PSI. 210,000 BTU.
Honeywell
V4295A1098
085267188968
1 In Stock
V4295A1106 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 1/2NPT with 1/4 NPT inlet & outl et pressure taps. Max pressure 5 PSI. 210 CFH. .16 amps.
Honeywell
V4295A1106
4046911014183
8 In Stock
V4295A1114 Honeywell 3/4 Solenoid Gas Vlv 120V NC
3/4 Solenoid Gas Vlv 120V NC * Normally closed solenoid gas valve. 120 volts. 3/4 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 5 PSI. 610 CFH. .2 amps.
Honeywell
V4295A1114
085267188982
2 In Stock
V4295A1122 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 1 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 5 PSI. 825 CFH. .2 amps.
Honeywell
V4295A1122
085267188999
6 In Stock
V4295A1130 Honeywell 1-1/4NPT Sol Gas Vlv NC 5PSI
1-1/4NPT Sol Gas Vlv NC 5PSI * Normally closed solenoid gas valve. 120 volts. 1-1/4 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 5 PSI. 1950 CFH. .55 amps.
Honeywell
V4295A1130
085267189002
1 In Stock
V4295A1148 Honeywell Normally closed solenoid gas valve.
Normally closed solenoid gas valve. 120 volts. 1-1/2 NPT with 1/4 NPT inlet & outlet pressure taps. Max pressure 5 PSI. 2270 CFH. .55 amps.
Honeywell
V4295A1148
085267189019
2 In Stock
V4295S1005 Honeywell 3/4 Solenoid Gas Vlv 120V NO
3/4 Solenoid Gas Vlv 120V NO * 3/4 inch normally open vent solenoid valve with 120vac coil. 2 psi maximum pressure.
Honeywell
V4295S1005
085267150033
4 In Stock
V4295S1013 Honeywell 1 Gas Vent Valve 120V NO
1 Gas Vent Valve 120V NO * 1 inch normally open vent solenoid valve with 120vac coil. 2 psi maximum pressure.
Honeywell
V4295S1013
4046911014251
4 In Stock