Categories
Brands
Limits and Cutouts
3L09-16 White Rodgers Emerson Limit Control Opens At 150 F
Limit Control Opens At 150 F Closes At 130 F Length 3.12 Inches. Therm-O-Disc 36T 612704
White Rodgers
3L09-16
786710092664
$14.20
EA
$34.08
5 In Stock
3L09-19 White Rodgers Board Mount Limit Control
Board Mount Limit Control Opens At 175 F Closes At 145 F Length 7 INCH Therm-O-Disc 36T 612712
White Rodgers
3L09-19
786710092695
$14.99
EA
$36.69
2 In Stock
3L09-7 White Rodgers Limit Control Bimetal Disc
Limit Control Bimetal Disc Opens At 175 F Closes At 145 F Length 3.12 INCH Therm-O-Disc York S1-025-35361-000 025-35361-000
White Rodgers
3L09-7
786710092572
$14.20
EA
$34.76
7 In Stock
A25CN-1C Johnson Controls Warm Air Limit Control W/Manual
Warm Air Limit Control W/Manual Reset; SPDT; Range: 25F To 215F; Adjustable Knob; Rod & Tube Type Sensing Element; with mounting flange; High Temperature Cut Out; Normally Installed In Return Duct Case Of Fire.
Johnson Controls
A25CN-1C
$157.94
EA
$394.84
2 In Stock
$7.74
EA
$18.33
Not in stock
HH22HA191 Carrier 190F Remote Cut-Out
190F Remote Cut-Out Limit Switch Auto Reset Open190/Close150 48" Cap Tube Auto Reset Rollout Switch
Carlyle Compressor
HH22HA191
00662441029110
$25.32
EA
$59.98
Not in stock
L59-3BA Camstat F568 3 Limit SPDT. Range 150-250F. Fixed
3 Limit SPDT. Range 150-250F. Fixed DiF30F. 5.8A @ 120V 2.9A @ 240V. OBSOLETE
Camstat
L59-3BA
688392605661
$37.15
EA
$90.95
1 In Stock
STC4283 Sealed Unit Parts In Line Thermal Cutoff 291F
In Line Thermal Cutoff 291F * In Line Thermal Cutoff One Time Limit Breaks At 291F (144C) Max Rating 10A@250Vac (15A@120Vac) Applications: Electric Heat And Heat Pump
Supco
STC4283
$1.11
EA
$4.08
7 In Stock
STC4300 Sealed Unit Parts In Line Thermal Cutoff 306F (152c)
In Line Thermal Cutoff 306F (152c) NO CERAMIC. * In Line Thermal Cutoff One Time Limit Breaks At 306F (152C) Max Rating 10A@250V (15A@120V) Use On Electric Heat And Heat Pumps
Supco
STC4300
$1.18
EA
$4.34
4 In Stock
STC4333 Sealed Unit Parts In Line Thermal Cutoff 333F
In Line Thermal Cutoff 333F * In Line Thermal Cutoff Limit Breaks At 333F (167C) Max. Rating 10A@250V (15A@120V) Use With Electric Heat And Heat Pumps
Supco
STC4333
$1.38
EA
$5.05
8 In Stock
STC5257 Sealed Unit Parts Thermal Cutoff With Ceramic Base
Thermal Cutoff With Ceramic Base Limit Breaks At 262F (128C) Max Rating 10A@250V (15A@120V) Use On Electric Heat And Heat Pumps 2 1/4 Tab Connectors. Sold individually; purchased as a two pack.
Supco
STC5257
$2.92
EA
$8.57
22 In Stock
STC5333 Sealed Unit Parts Supco Thermal Cutoff W/ Ceramic Base
Thermal Cutoff W/ Ceramic Base Limit Breaks At 333F (167C) Max Rating 10A@250V (15A@120V) Use On Electric Heat And Heat Pumps 2 1/4 Tab Connectors
Supco
STC5333
687152031924
$2.85
EA
$8.36